Skip to content

ADVANCED GLASS

HTCC Green Sheets

Four alumina HTCC green sheet (green tape) grades from 96% to 99.98% Al₂O₃, with matched tungsten pastes, for ceramic package and multilayer evaluation

Technical inquiry ↗

PRODUCT RANGE

Confirmed catalog scope

Grades
HTK96, HTKAHP100, HTKA9996, HTKAHP200
Sheet size
6, 8, 15 inch or □100–400 mm, depending on grade
Green thickness
20–500 μm depending on grade
Alumina content
96% – ≥99.98%

KEY FEATURES

Selection and evaluation points

  • Four alumina grades: 96%, >97%, ≥99.6% and ≥99.98% Al₂O₃
  • HTKAHP100: 36 W/m·K thermal conductivity and firing at 1430–1530 °C
  • Typical XY firing shrinkage from 13.0% to 16%, depending on grade
  • Matched tungsten pastes for via filling, via wall coating and screen printing
  • Trial lots from 100 sheets

Applications

  • Ceramic electronic packages
  • Multilayer alumina substrates
  • High-temperature co-fired structures

Final suitability, compatibility and qualification must be confirmed for the actual design and process

HTCC EVALUATION

What should buyers compare when evaluating alumina HTCC green sheets?

Review alumina grade, green-sheet thickness and usable dimensions, shrinkage behavior, conductor compatibility and co-firing conditions together · A higher alumina purity alone does not establish suitability for an existing multilayer process · Hai Tak lists four alumina HTCC grades from 96% to 99.98% Al₂O₃, plus matched tungsten pastes; dimensions and material properties must be checked against the actual drawing and qualification tests

Send the target fired dimensions, layer count, required conductor system, firing profile, relevant test methods and estimated trial quantity · Listed values support initial selection, not automatic production qualification

View detailed technical tables

HTCC

Available HTCC Grades

PropertyHTK96HTKAHP100HTKA9996HTKAHP200
Alumina content96%>97%≥99.6%≥99.98%
Dielectric constant @ 1 MHz9.8±0.29.39.5–10.59.5–10.5
Dielectric loss @ 1 MHz≤0.001<0.4×10⁻⁴≤2.5×10⁻⁴≤2.5×10⁻⁴
Dielectric constant @ 10 GHz9.7±0.2   
Dielectric loss @ 10 GHz≤0.001   
CTE (ppm/°C)5.6 (@300 °C)6.3 (RT–300 °C)6.5–7.5 (20–500 °C)6.5–7.5 (20–500 °C)
Thermal conductivity (W/m·K)≥1836≥28≥28
Fired density (g/cm³)≥3.6>3.8≥3.87≥3.9
Flexural strength, 3-point (MPa)≥350>380≥400≥400
XY firing shrinkage (%)13.6±0.513.0–14.015.116
Z firing shrinkage (%)2819–232320
Surface roughness Ra (nm) 100≤100≤100
Firing1520–1560 °C, 2 h1430–1530 °C, 1 h1500–1550 °C, 3 h1450–1550 °C, 3 h
Co-fired conductorW, Mo WW
Sheet size6, 8, 15 inch□100–400 mm6, 8, 15 inch6, 8, 15 inch
Green thickness20–500 μm, ±5%75–150 μm, <±10%20–500 μm, ±5%20–500 μm, ±5%
Green sheet tensile strength (MPa)>3.0   
Green density (g/cm³)2.2±0.2   

Values are typical results under laboratory conditions and may vary with processing and test conditions · HTKAHP100 shrinkage values are reference figures measured at 100 μm sheet thickness and 34.3 MPa press pressure · Website values are not guaranteed values; the current controlled TDS takes priority

MATCHED CONDUCTOR

Matched tungsten pastes

HTK supplies three tungsten pastes matched to HTK-series alumina green sheets, covering via filling, via wall coating and screen printing. They are qualified with the HTKA9996 and HTKAHP200 grades and co-fire at 1520–1560 °C in a hydrogen–nitrogen atmosphere. Ordering tape and paste together lets you evaluate one material system instead of two.

See tungsten pastes for HTCC

  • 01

    HTK-4T · Via filling

  • 02

    HTK-1G · Via wall coating

  • 03

    HTK-2Y · Screen printing

SAMPLES

Sample evaluation and small lots

Trial lots start from 100 sheets. Sheet format and thickness depend on the grade: 6, 8 and 15 inch at 20–500 μm for HTK96, HTKA9996 and HTKAHP200; □100–400 mm at 75–150 μm for HTKAHP100. Send us the six items below and we will confirm availability, lead time and a quotation.

Request an evaluation lot ↗

  • 01

    Grade (HTK96, HTKAHP100, HTKA9996, HTKAHP200, or not sure)

  • 02

    Sheet size

  • 03

    Green thickness (μm)

  • 04

    Quantity (sheets)

  • 05

    Conductor system and firing atmosphere

  • 06

    Application and target fired dimensions

FAQ

HTCC green sheet (green tape) FAQ

What sheet sizes and thicknesses are available?

It depends on the grade. HTK96, HTKA9996 and HTKAHP200 come as 6, 8 and 15 inch sheets at 20–500 μm (±5%). HTKAHP100 comes as □100–400 mm sheets at 75–150 μm (<±10%). Other sizes and thicknesses can be made to order.

What is the firing shrinkage?

Typical XY shrinkage is 13.6±0.5% for HTK96, 13.0–14.0% for HTKAHP100, 15.1% for HTKA9996 and 16% for HTKAHP200. Typical Z shrinkage is 28%, 19–23%, 23% and 20%. These are laboratory values; confirm them under your own lamination and firing profile.

Which conductors can be co-fired?

HTK96 co-fires with tungsten and molybdenum pastes. HTK also supplies matched tungsten pastes for via filling, via wall coating and screen printing, qualified with the HTKA9996 and HTKAHP200 grades.

What feature sizes can the green sheet support?

HTK96 supports 100 μm line width, 100 μm spacing and 100 μm via diameter, with up to 100 laminated layers.

How should green sheets be stored?

Keep them sealed in a clean room-temperature environment, 18–30 °C and 20–60% RH. Under these conditions the storage life of HTK96 is one year.

Can I order a small quantity for evaluation?

Yes. Trial lots start from 100 sheets, and the same grades are available for volume supply.

PRODUCT CATALOG

HTCC Green Sheets

View catalog ↗Download PDF

BROWSE THE APPROVED CATALOG

HTCC Green Sheets

Select a page title to preview the matching PDF page below · The approved PDF file is unchanged

Page 1 / 8Open original PDF ↗

Select a title to load the preview

TECHNICAL REVIEW

Share your application and evaluation conditions

HTK can coordinate current controlled data, samples and project-specific manufacturing review

Contact HTK